Skip to content

S5-100 Float Valve - Installation and Maintenance

THE SEries 5 VALVEs INCLUDE

S5-Series Main.b - 500
  • 2 brass float rods (2”, 5 ¾”)
  • Float rod weight
  • Float rod stop gasket (to keep weight in place when using longer brass rods)
  • Wing nut, bolt, star washer (to attach brass float rod to valve arm)
  • Plastic Float 4”
  • Valve Unit (including filter and diaphragm)

VALVE ASSEMBLY

  • The valve comes with two different size brass float rods to customize the length to suit your application.
  • Choose the brass float rod that meets your installation needs and insert into the plastic float.  The float rods are easily interchanged by unscrewing the float rod from the plastic float.  The larger rods have a rubber stop gasket to prevent the rod weight from sliding down the brass float rod.
  • The smaller float rod does not require this rubber stop gasket.
  • Other optional longer float rods are available to better suit your application if needed.
  • After your desired float rod selection and insertion into the plastic float, connect the other end of the brass float rod to the valve arm by using the wing nut, bolt, and star washer.  The star washer goes between the valve rod and the brass float rod.
  • The S5-Series valve comes with an inlet adapter of your choosing permanently attached to the valve body that coincides with the model number. 
  • Attempting to remove this adapter will cause a fail point in this connection which in-turn may result in leakage and is not covered under warranty.  To clean the filer, see maintenance below.

VALVE INSTALLATION

  • Prior to installation ensure the feed lines are flushed and free of debris.
  • Make sure that you chose the correct model to match your feed line diameter.
  • Using Teflon tape, turn the assembly into the feed line and hand tighten making sure the outlet is facing down into the tank.
  • Adjust the brass rod to the desired tank level.

MAINTENANCE

If the valve is not operating properly

  1. Check the valve rod adjustment to assure proper tank level is maintained.
  2. Check diaphragm and filter condition
    • Turn off the feed line. 
    • Remove the six stainless steel screws holding the valve bonnet in place and remove bonnet.
    • Remove diaphragm assembly and check for debris buildup and flush with clean water if debris is present.
    • Check diaphragm assembly for signs of rupture. If ruptured replace diaphragm assembly. (part# S5-100D)
    • Using the six stainless screws reassemble the valve and return to service making sure the float is adjusted properly.